Government of Canada
Symbol of the Government of Canada

CCBFC Standing Committee Activities

The Canadian Commission on Building and Fire Codes (CCBFC) has approved the following Code development activities for the 2010-2015 Code cycle and instructed its Standing Committees to prepare work plans focusing on these issues.

Activity Code Committees
All Committees
Large Farm Building Requirements
Review of Referenced Standards
SC Building and Plumbing Services (BPS)
Air Admittance Valves NPC BPS
Cellular Core NPC BPS
Cleanouts NPC BPS
Combo Domestic Water Heaters NBC, NPC BPS
Development of Explicit Ventilation Requirements NBC Part 6 BPS
Drinking Water Treatment Systems NPC BPS
Ferrous Pipes and Fittings (Stainless Steel) NPC BPS
Frames and Covers for Maintenance Holes & Catchbasins NPC BPS
Grease Interceptors NPC BPS
Intents and Application Statements NBC Part 6, NPC BPS
Lightning Protection Systems NBC Part 6 BPS
Profile Polyethylene Drainage Products NPC BPS
Seismic Protection of Plumbing Systems NPC BPS
TIAC Best Practices Guide NBC, NPC BPS
Vacuum Breakers (spill resistant type) NPC BPS
Water Use Efficiency and Grey Water NBC, NPC BPS
Humidity Control NBC Part 6 BPS, ES
SC Earthquake Design (ED)
Application of 4 second Force Cutoff NBC ED
Base Isolation Systems NBC ED
Damping Systems NBC ED
Earthquake - Compatibility with Referenced Standards NBC ED
Earthquake - Displacement Based Design NBC ED
Earthquake - Flexible Diaphragm NBC ED
Earthquake - Whole Structure NBC ED
Foundation Factors NBC ED
Inclined Columns NBC ED
Racking Storage Systems NBC ED
Seismic Design of Elevator Supporting Structures NBC ED
Seismic Risk Reduction of Operational and Functional Components NBC ED
Seismicity NBC ED
Structures in Low Hazard Zones NBC ED
SC Energy Efficiency in Buildings (EEB)
Energy Target NECB EEB
Equipment Efficiencies and Trade-off Coefficients affected by Energy Efficiency Act NECB EEB
Guidance Document for the Provinces/Territories NECB EEB
Lighting and Electrical Power Items NECB EEB
Piping and Duct Insulation for HVAC and Service Water Heaters NECB EEB
Semi-Heated Buildings NECB EEB
User's Guide NECB EEB
Air Barrier Assembly Testing NBC Part 5, NECB EEB, ES
SC Environmental Separation (ES)
Dynamic Wind Uplift Resistance of Mechanically Attached Membrane-Roofing Systems NBC Part 5 ES
Materials with Multiple Functions NBC Appendix Note ES
Performance-Based Requirements NBC Part 5 ES
Review ANSI/HPVA HP-1 (standard for hardwood and decorative plywood) NBC Part 5 ES
Review ASTM C840, C841 and C842 (standards for gypsum board and gypsum plaster) NBC Part 5 ES
Review of four ULC Thermal Insulation Standards NBC Part 5 ES
Update of Part 5 User's Guide NBC Part 5 ES
Window Walls and Curtain Walls NBC Part 5 ES
Windows' Failure NBC Part 5 ES
Airborne Sound Transmission NBC Part 5 & 9 ES, HSB
Exterior Insulation and Finish Systems NBC Part 5 & 9, NECB ES, HSB, EEB
Green Roofs NBC Part 5 ES, FP, BPS
Roofing, Dampproofing and Waterproofing NBC Part 5 & 9 ES, HSB
SC Fire Protection (FP)
Buildings or Parts thereof in Subsection 3.1.5. (Noncombustible Construction) NBC Part 3 FP
Combustible Components for Exterior Walls NBC Part 3 FP
Composite Steel Beams (Alternative Structural Design) NBC Part 3 FP
Firewalls NBC Part 3 & 9 FP
Requirements for Fabric-Covered Buildings NBC Part 3 FP
Review and Revision of Appendix D-2.3 (Component Additive Method) NBC FP
Slim Floor Construction / Composite Steel Beam NBC Part 3 FP
Combustible Penetrations Through Fire Separations NBC Part 3 & 9 FP, HSB
Height and Area Limits for Wood-Frame Construction NBC Part 3 FP, BPS, ED, ES, EEB, SD, UE
Smoke Tightness of Closures in Fire Separations NBC Part 3, 6 & 9 FP, HSB, BPS
Technical Differences - Fire Protection - Firewalls NBC Part 3 & 9 FP, HSB
Use and Protection of Foamed Plastics in Building Construction NBC Part 3 & 9 FP, HSB
SC Hazardous Materials and Activities (HMA)
Classification for Strong Base and Acid NFC HMA
Classification of Dangerous Goods - Storage Requirements NFC HMA
Distance Between Aboveground Storage Tanks (Clearance Requirements) NFC HMA
Distilleries and Ethanol Refineries NFC HMA
Fuel-Dispensing Stations NFC HMA
Hot Works NFC HMA
Vehicle and Storage Tank of Dangerous Goods Hazards NFC HMA
Cross-Referencing and Relocating Requirements in the NFC and NBC NBC, NFC HMA, FP, UE, BPS
Review Fire Safety Plan Requirements NFC HMA, FP, UE
SC Housing and Small Buildings (HSB)
Basements NBC HSB
Depressurization - Limit Exhaust Capacity for Exhaust-Only Systems NBC Part 9 HSB
Illustrated Guide to Part 9 - NBC 2010 NBC Part 9 HSB
Insulated Concrete Form Construction NBC HSB
Low Permeance Materials NBC Part 5 HSB
Pneumatic Nailing NBC Part 9 HSB
Protection Above Ranges NBC Part 9 HSB
Referenced Standard CSA A82-12006 (masonry terminology)  NBC HSB
Slope Stability NBC Part 9  HSB
Energy Efficiency for Housing and Small Buildings NBC HSB, EEB
Exposed Building Face NBC HSB, FP
Grab Bars for Tubs & Showers NBC Part 9 HSB, UE
Hollow Masonry Veneer NBC Part 9 HSB, ES
Service Lines Under Buildings NBC HSB, FP
Snow Loads NBC Part 4 & 9 HSB, SD
SC Structural Design (SD)
Adaptation to Climate Change NBC SD
Commentary Material Relocation NBC SD
Definitions for Low, Normal, High Importance Categories NBC SD
Live Load & Snow Combination NBC SD
Live Load Due to Use and Occupancy NBC Part 4 & 9 SD
Review Definition of Post-Disaster Building NBC SD
Review of Importance Category Classification NBC SD
Serviceability NBC SD
Snow Build-Up on Canopies NBC SD
Snow Commentary - Built-up Snow Load NBC SD
Snow Density NBC SD
Structural Design of Glass NBC SD
Wind Uplift on Canopies NBC SD
ASTM E 1300 Glass Standard NBC SD, HSB
Climatic Loads NBC SD, HSB
Risk - Snow, Wind and Earthquake NBC SD, ED
Solar Collectors NBC, NPC, NECB SD, HSB
Storage Garage - Definition NBC Div.A SD, BPS
SC Use and Egress (UE)
Barrier-Free Design NBC Part 3 UE
Exit Widths NBC Part 3 UE
Occupant Load Calculation in Assembly Occupancies NBC Part 3, NFC UE
Revision of Subsection 3.3.2. (Assembly Occupancy) NBC Part 3 UE
Wayguidance NBC Part 3 & 9 UE
Fire Alarm and Detection Systems NBC Part 3 UE, HSB
Security Systems Affecting Egress NBC Part 3 & 9 UE, HSB
Stairs, Ramps, Handrails, Guards NBC Part 3 & 9 UE, HSB
Technical Differences Within NBC Part 3 & 9 NBC Part 3 & 9 UE, HSB